MILK COOLER 4L T
FOREWORD
The purpose of this document is to provide important information regarding the installation, use and maintenance of the cooler. Before any operation, you should read carefully the information contained in this manual. The manufacturer assumes no liability for parts or labor coverage for component failure or other damages resulting from improper usage, installation of failure to clean and/or maintain product as set forth in these instructions.
GENERAL USE
The cooler is not designed for external (outdoor) placement or environments that subject it to the actions of atmospheric agents (rain, direct sun light).
ATTENTION! The manufacturer is not responsible for damages resulting from the improper use of the product.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not Store explosive substances such as aerosol cans with a flammable propellant in this appliance.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
TESTING
The cooler is shipped ready for use.
Press (1.) button 0.5 second then press (3.) button on the control panel to decrease the temperature and the (4.) button to increase the temperature inside the cooler.
Temperature will flash for confirmation. The temperature range is from -1°C to 5°C.
Press (2) button once to turn the light on/off . (for model BC9CN, BR9CN).
The milk will be under 4 °C
We don’t recommend customer to adjust. Because the regulation too cold Setting can cause the freezing of the products. The best cooling performance is achieved if the unit is optimally filled and the air circulation inside the unit is nobstructed by the products inside the refrigerator.
RESPONSIBILITY OF THE CUSTOMER
Ensure that the electrical outlet is connected effectively to earth (ground), suitable to provide the voltage indicated on the data plate. Make sure that the cooler is placed on a level surface.
TECHNICAL DATA
MATERIALS AND REFRIGERANTS
Interior or exterior surfaces that come into contact with the products are made of galvanized steel. Aluminium or non-toxic plastic materials.
The Refrigerant used is approved by government regulations. The type and quantity of the gas charged, in the refrigeration unit, is indicated on the data plate.
INSTALLATION
For safe proper operation, follow the manufacturer´s instructions reported in this section.
POSITIONING
The cooler must be placed in an adequately ventilated room. Keep away from heat sources, such as radiators or air conditioning pipes. Allow free air circulation to the refrigerator unit.
The ambient temperature must not be higher than 40°C. This appliance climate class is 3, 4, 5.
Cooler Leveling: To provide the best performance the cooler must remain level.
ELECTRICAL CONNECTION
WARNING DO NOT USE EXTENSION CORDS
The cooler works on single-phase voltage (220-240V 50/60Hz) power supply. To switch on the cooler, insert the plug into the outlet.
Ensure that:
The electrical outlet must be provided with an efficient ground, the voltage and the frequency of the electrical line matches those indicated on the data plate. If unsure about the efficiency of the ground, have your electrical circuit checked by qualified technician. When the cooler is operating, check that the supply voltage is not dropping or increasing under/over +10% the rated voltage (187 Volts to 242 Volts). If the light is damaged, it must be replaced with a same size, power and shape one and must be replaced by the manufacturer or its service agent.
Check the contents of the package:
Place the Milk Cooler on a firm, flat surface next to the coffee machine.
For use next to an OptiMe coffee machine, new feet must be mounted.
Fix the feet with a height of 50 mm. (4x)
Remove the plug to clear hole for the milk hose.
Place plug in the hole.
Remove inside part of the plug to enlarge hole for milk hose.
This step must be carried out for the milk hose of the Animo Optime coffee machine.
Pass the milk hose through the hole in the side panel of the cooler.
Milk hose will be supplied with the coffee machine.
Connect the milk hose to the milk input nozzle of the coffee machine.
Slide the milk cooler next to the coffee machine.
NOTE: the milk container can be filled with milk up to its max capacity (4,5 ltr).
Instead of the milk container, you can also use milk cartons in the cooler.
Connect the Milk Cooler to a 230 V mains power socket with the provided power cable.
Before cleaning the cooler always remember to unplug it.
Unplug the cooler at the electrical outlet; never pull the service cord.
Clean the inside cabinet of cooler with a clean damp cloth or with neutral soap.
Avoid damage by never using abrasive or flammable cleaning products.
Clean the condenser at least once a month with a vacuum cleaner or a brush to eliminate the dust accumulation.